Viimeisin päivitys :
03/05/2024
Syöpälääke   Cytarabine  
Injektioneste
Stabilius liuoksessa Stabilius seoksissa Tekijät, jotka vaikuttavat stabiliuteen Yhteensopivuus Antotapa Viitteet Pdf
   Kemiallinen rakenne  

Kauppanimi   Kauppanimi     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Alexan Chile, Egypti, Etelä-Afrikka, Hollanti, Itävalta, Kolumbia, Luxemburg, Saksa, Saudi-Arabia, Thaimaa, Turkki, Unkari, Venäjä, Yhdistyneet arabiemiirikunnat
Alexane Iran
Ara Cell Portugali, Saksa
Arabine Islanti, Ruotsi, Suomi, Tanska
Aracytin Brasilia, Chile, Egypti, Italia, Kolumbia, Kreikka
Aracytine Kolumbia, Marokko, Ranska
Cancyt Intia
Citab Brasilia
Citarabina Argentiina, Chile, Ecuador, Espanja, Italia, Kolumbia, Meksiko
Cylocide Japani
Cytaban Kolumbia
Cytaloxan Portugali
Cytarabine Australia, Belgia, Egypti, Irlanti, Iso-Britannia, Kanada, Malesia, New Zealand, Suomi, Tanska, Yhdistyneet arabiemiirikunnat, Yhdysvallat
Cytarax Brasilia, Meksiko
Cytonal Turkki
Cytosafe Iso-Britannia
Cytosar Belgia, Etelä-Afrikka, Hollanti, Iran, Irlanti, Itävalta, Kanada, Kroatia, Luxemburg, Malesia, Norja, Portugali, Puola, Saudi-Arabia, Sveitsi, Tanska, Unkari, Venezuela, Yhdistyneet arabiemiirikunnat
Ifarab Meksiko
Laracit Chile, Kolumbia, Meksiko
Medsara Meksiko
Novutrax Kolumbia, Meksiko
Oncorab Venezuela
Tabine Ecuador
Udicil Saksa
Zuphacit Meksiko
Viitteet   Injektioneste   Viitteet : Cytarabine  
Tyyppi Julkaisu
3 Lehti Trissel LA, Martinez JF.
Compatibility of amifostine with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1995 ; 52: 2208-2212.
31 Lehti Zhang Y, Xu QA, Trissel LA, Gilbert DL.
Physical and chemical stability of methotrexate sodium, cytarabine, and hydrocortisone sodium succinate in Elliott’s B solution.
Hosp Pharm 1996 ; 31: 965-970.
57 Lehti Mayron D, Gennaro AR.
Stability and compatibility of granisetron hydrochloride in IV solutions and oral liquids and during simulated Y-site injection with selected drugs.
Am J Health-Syst Pharm 1996 ; 53: 294-304.
81 Lehti Trissel LA, Martinez JF.
Compatibility of piperacillin sodium plus tazobactam with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1994 ; 51: 672-678.
84 Lehti Trissel LA, Martinez JF.
Visual, turbidimetric, and particle-content assessment of compatibility of vinorelbine tartrate with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1994 ; 51: 495-499.
85 Lehti Trissel LA, Bready BB.
Turbidimetric assessment of the compatibility of taxol with selected other drugs during simulated Y-site injection.
Am J Hosp Pharm 1992 ; 49: 1716-1719.
91 Lehti Lober CA, Dollard PA.
Visual compatibility of gallium nitrate with selected drugs during Y-site injection.
Am J Hosp Pharm 1993 ; 50: 1208-1210.
99 Lehti Trissel LA, Martinez JF.
Compatibility of aztreonam with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1995 ; 52: 1086-1090.
132 Lehti Najari Z, Rusho WJ.
Compatibility of commonly used bone marrow transplant drugs during Y-site delivery.
Am J Health-Syst Pharm 1997 ; 54: 181-184.
142 Lehti Rochard EB, Barthes DMC, Courtois PY.
Stability of fluorouracil, cytarabine, or doxorubicin hydrochloride in ethylene vinylacetate portable infusion-pump reservoirs.
Am J Hosp Pharm 1992 ; 49: 619-623.
150 Lehti Aujoulat P, Coze C, Braguer D, Raybaud C.
Physicochemical compatibility of methotrexate with co-administered drugs during cancer chemotherapy regimens.
J Pharm Clin 1993 ; 12: 31-35.
152 Lehti Chevrier R, Sautou V, Pinon V, Demecop F, Chopineau J.
Stability and compatibility of a mixture of the anti-cancer drugs etoposide, cytarabine and daunorubicine for infusion.
Pharm Acta Helv 1995 ; 70: 141-148.
169 Lehti Trissel LA, Martinez JF.
Physical compatibility of melphalan with selected drugs during simulated Y-site administration.
Am J Hosp Pharm 1993 ; 50: 2359-2363.
184 Lehti Stewart JT, Warren FW, King DT, Fox JL.
Stability of ondansetron hydrochloride and five antineoplasic medications.
Am J Health-Syst Pharm 1996 ; 53: 1297-1300.
244 Lehti Trissel LA, Martinez JF.
Compatibility of filgrastim with selected drugs during simulated Y-site administration.
Am J Hosp Pharm 1994 ; 51: 1907-1913.
249 Lehti Trissel LA, Martinez JF.
Compatibility of thiotepa (lyophilized) with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1996 ; 53: 1041-1045.
251 Lehti Trissel LA, Gilbert DL, Martinez JF.
Compatibility of doxorubicin hydrochloride liposome injection with selected other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 2708-2713.
253 Lehti Trissel LA, Chandler SW, Folstad JT.
Visual compatibility of amsacrine with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1990 ; 47: 2525-2528.
300 Lehti Trissel LA, Gilbert DL, Martinez JF.
Compatibility of propofol injectable emulsion with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1287-1292.
301 Lehti Trissel LA, Gilbert DL, Martinez JF, Baker MB, Walter WV, Mirtallo JM.
Compatibility of parenteral nutrient solutions with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1295-1300.
307 Lehti Trissel LA, Martinez JF.
Compatibility of allopurinol sodium with selected drugs during simulated Y-site administration.
Am J Hosp Pharm 1994 ; 51: 1792-1799.
331 Lehti Marquardt ED.
Visual compatibility of hydroxyzine hydrochloride with various antineoplasic agents.
Am J Hosp Pharm 1988 ; 45: 2127.
334 Lehti Trissel LA, Tramonte SM, Grilley BJ.
Visual compatibility of ondansetron hydrochloride with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1991 ; 48: 988-992.
335 Lehti Trissel LA, Bready BB, Kwan JW, Santiago NM.
Visual compatibility of sargramostim with selected antineoplasic agents, anti-infectives, or other drugs during simulated Y-site injection.
Am J Hosp Pharm 1992 ; 49: 402-406.
431 Lehti McRae MP, King JC.
Compatibility of antineoplastic, antibiotic and corticosteroid drugs in intravenous admixtures.
Am J Hosp Pharm 1975 ; 33: 1010-1013.
491 Lehti Turowski RC, Durthaler JM.
Visual compatibility of idarubicin hydrochloride with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1991 ; 48: 2181-2184.
492 Lehti Trissel LA, Parks NPT, Santiago NM.
Visual compatibility of fludarabine phosphate with antineoplastic drugs, anti-infectives, and other selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1991 ; 48: 2186-2189.
643 Lehti Seargeant LE, Kobrinsky NL, Sus CJ, Nazeravich DR.
In vitro stability and compatibility of daunorubicin, cytarabine, and etoposide.
Cancer Treat Rep 1987 ; 71: 1189-1192.
739 Lehti Cradock JC, Kleinmann LM, Rahman A.
Evaluation of some pharmaceutical aspects of intrathecal methotrexate sodium, cytarabine and hydrocortisone sodium succinate.
Am J Hosp Pharm 1978 ; 35: 402-406.
844 Lehti Rochard E, Chapelle G, Bouquet S, Barthes D, Courtois PH.
Stability of fluorouracil and cytarabine in ethylvinylacetate containers.
J Pharm Clin 1989 ; 9: 31-35.
850 Lehti Munson J, Kubiak EJ, Cohon MS.
Cytosine arabinose stability in intravenous admixtures with sodium bicarbonate and in plastic syringes.
Drug Intell Clin Pharm 1982 ; 16: 765-767.
905 Lehti Trissel LA, Martinez JF.
Screening teniposide for Y-site physical incompatibilities.
Hosp Pharm 1994 ; 29: 1010-1017.
921 Lehti Trissel LA, Gilbert DL, Martinez JF.
Incompatibility and compatibility of amphotericin B cholesteryl sulfate complex with selected other drugs during simulated Y-site administration.
Hosp Pharm 1998 ; 33: 284-292.
978 Lehti Dick DM, Woloschuk DMM.
Methotrexate and cytarabine for intrathecal administration.
Can J Hosp Pharm 1994 ; 47: 147.
1028 Lehti Cheung YW, Vishnuvajjala BR, Flora KP.
Stability of cytarabine, methotrexate sodium, and hydrocortisone sodium succinate admixtures.
Am J Hosp Pharm 1984 ; 41: 1802-1806.
1229 Lehti Weir PJ, Ireland DS.
Chemical stability of cytarabine and vinblastine injections.
Br J Pharm Pract 1990 ; 12: 53-54, 60.
1410 Lehti Trissel LA, Martinez JF, Simmons M.
Compatibility of etoposide phosphate with selected drugs during simulated Y-site injection.
J Am Pharm Assoc 1999 ; 39: 141-145.
1415 Lehti Trissel L.A, Gilbert D.L, Martinez J.F, Baker M.B, Walter W.V, Mirtallo J.M.
Compatibility of medications with 3-in-1 parenteral nutrition admixtures.
JPEN 1999 ; 23: 67-74.
1423 Lehti Trissel LA, Martinez JF, Gilbert DL.
Compatibility of gemcitabine hyrochloride with 107 selected drugs during simulated Y-site injection.
J Am Pharm Assoc 1999 ; 39: 514-518.
1496 Lehti Trissel LA, Martinez JF, Gilbert DL.
Screening cladribine for Y-site physical compatibility with selected drugs.
Hosp Pharm 1996 ; 31: 1425-1428.
1501 Lehti Beitz C, Bertsch T, Hannak D, Schrammel W, Einberger C, Wehling M.
Compatibility of plastics with cytotoxic drug solutions - comparison of polyethylene with other container materials.
Int J Pharm 1999 ; 185: 113-121.
1520 Laboratorio Etude de stabilité des médicaments en Ecoflac®
B Braun 2001
1625 Lehti Trissel LA, Saenz C, Williams YW, Ingram D.
Incompatibilities of lansoprazole injection with other drugs during simulated Y-site coadministration.
Int J Pharm Compound 2001 ; 5: 314-321.
1661 Lehti Trissel LA, King KM, Zhang Y, Wood AM.
Physical and chemical stability of methotrexate, cytarabine, and hydrocortisone in Elliott’s B Solution for intrathecal use.
J Oncol Pharm Practice 2002 ; 8: 27-32.
1925 Lehti Trissel LA , Williams KY, Gilbert DL.
Compatibility screening of linezolid injection during simulated Y-site administration with other drugs and infusion solutions.
J Am Pharm Assoc 2000 ; 40: 515-519.
1953 Lehti Trissel LA, Saenz CA, Ogundele AB, Ingram DS.
Physical compatibility of pemetrexed disodium with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2004 ; 61: 2289-2293.
1982 Lehti Trissel LA, Ogundele AB.
Compatibility of anidulafungin with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2005 ; 62: 834-837.
2247 Lehti Chan P, Heatherly K, Kupiec T.C, Trissel L.A.
Compatibility of caspofungin acetate injection with other drugs during simulated Y-site coadministration.
Int J Pharm Compound 2008 ; 12, 3: 276-278.
2255 Laboratorio Stability of Alexan "Ebewe" infusion solutions.
Ebewe Pharma 2007
3275 Lehti D'Hondt M, Vangheluwe E, Van Dorpe S, Boonen J, Bauters T, Pelfrene B, Vandenbroucke J, Robays H, De Spiegeleer B
Stability of extemporaneously prepared cytarabine, methotrexate sodium, and methylprednisolone sodium succinate
Am J Health-Syst Pharm 2012 ; 69: 232-240.
3474 Laboratorio Fluorouracil - Summary of Product Characteristics
Accord Healthcare Limited 2009
3540 Laboratorio Heparin sodium - Summary of Product Characteristics.
Wockhardt 2010
3580 Laboratorio Cytarabine Accord - Résumé des caractéristiques du produit
Accord Healthcare France 2016
3585 Laboratorio Benzylpenicillin sodium - Summary of Product Characteristics
Genus Pharmaceuticals 2008
3637 Laboratorio Methotrexate (Methotrexate solution for injection®) - Summary of Product Characteristics
Hameln Pharmaceuticals 2014
4455 Lehti Ben Ayed W, Drira C, Ali Soussi M, Ouesleti H, Hamdene B, Khrouf M, Safta F, Fradi I.
Physical and chemical stability of cytarabine in polypropylene syringes.
J Oncol Pharm Practice 2020 online first

  Mentions Légales