Ultimele actualizari :
06/05/2024
Antiaritmic   Amiodarone hydrochloride  
Injectabil
Capsulă Soluţie orală
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie Pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Acrodarona Ecuador
Amidovin Turcia
Amiocar Argentina, Peru
Amiodar Italia
Amiodaron Germania, Norvegia, Suedia
Amiodarona Argentina, Chilli, Columbia, Ecuador, Mexic, Peru
Amiodarone Australia, Canada, Iran, Italia, Luxemburg, Marea Britanie, Noua Zeelandă, SUA
Amiohexal Germania
Amiokordin Polonia, Romania, Ungaria
Amiorit Venezuela
Ancoron Brazilia
Angoron Grecia
Asulblan Argentina
Atlansil Argentina, Brazilia, Chilli, Ecuador, Peru
Cardasol India
Cardichek India
Cardio Egipt
Cirtrent Mexic
Cordalin Turcia
Cordarex Germania
Cordarone Arabia Saudita, Australia, Belgia, Chilli, Columbia, Danemarca, Ecuador, Elvetia, Emiratele Arabe Unite, Finlanda, Franta, Irlanda, Islanda, Italia, Luxemburg, Malaezia, Marea Britanie, Maroc, Mexic, Norvegia, Noua Zeelandă, Olanda, Polonia, Portugalia, SUA, Suedia, Tunisia, Turcia, Ungaria
Duron India
Eudarona Venezuela
Eurythmic India
Farcodarone Egipt
Ronecard Egipt
Sedacoron Arabia Saudita, Austria, Polonia, Romania, Tunisia
Sedacorone Iran
Trangorex Spania, Venezuela
Bibliografie   Injectabil   Bibliografie : Amiodarone hydrochloride  
Tip Publicare
200 Ziar Korth-Bradley JM, Ludwig S, Callaghan C.
Incompatibility of amiodarone hydrochloride and sodium bicarbonate injections.
Am J Health-Syst Pharm 1995 ; 52: 2340.
205 Ziar Strozyk WR, Williamson R, Thompson D.
Incompatibility of amiodarone hydrochloride and evacuated glass bottles.
Am J Health-Syst Pharm 1996 ; 53: 184.
242 Ziar Campbell S, Nolan PE, Bliss M, Wood R, Mayersohn M.
Stability of amiodarone hydrochloride in admixtures with other injectable drugs.
Am J Hosp Pharm 1986 ; 43: 917-921.
295 Ziar Yamashita SK, Walker SE, Choudhury T, Iazzetta J.
Compatibility of selected critical care drugs during Y-site administration.
Am J Health-Syst Pharm 1996 ; 53: 1048-1051.
379 Ziar Weir SJ, Szucs Myers VA, Bengtson KD, Ueda CT.
Sorption of amiodarone to polyvinyl chloride infusion bags and administration sets.
Am J Hosp Pharm 1985 ; 42: 2679-2683.
385 Ziar Benedict MK, Roche VF, Banakar UV, Hilleman DE.
Visual compatibility of amiodarone hydrochloride with various antimicrobial agents during simulated Y-site injection.
Am J Hosp Pharm 1988 ; 45: 1117-1118.
647 Ziar Pramar YV.
Chemical stability of amiodarone hydrochloride in intravenous fluids.
Int J Pharm Compound 1997 ; 1: 347-348.
925 Ziar Dupuis LL, Trope A, Giesbrecht E, Wong B.
Compatibility and stability of propafenone hydrochloride with five critical-care medications.
Can J Hosp Pharm 1998 ; 51: 55-57.
1036 Ziar Hasegawa GR, Eder JF.
Visual compatibility of amiodarone hydrochloride injection with other injectable drugs.
Am J Hosp Pharm 1984 ; 41: 1379-1380.
1041 Ziar Hasegawa GR, Eder JF.
Visual compatibility of dobutamine hydrochloride with other injectable drugs.
Am J Hosp Pharm 1984 ; 41: 949-951.
1232 Ziar Beatson C, Taylor A.
A physical compatibility study of furosemide & flucloxacillin injections.
Br J Pharm Pract 1987 ; 9: 223-226, 236.
1508 Ziar Voirol P, Berger-Gryllaki M, Pannatier A, Eggimann P, Sadeghipour F.
Visual compatibility of insulin aspart with intravenous drugs frequently used in ICU.
EJHP 2015 ;22:123-124.
1611 Ziar Chalmers JR, Bobek MB, Militello MA.
Visual compatibility of amiodarone hydrochloride injection with various intravenous drugs.
Am J Health-Syst Pharm 2001 ; 58: 504-506.
1712 Ziar Trissel LA, Saenz CA.
Compatibility screening of Precedex during simulated Y-site administration with other drugs.
Int J Pharm Compound 2002 ; 6: 230-233.
1713 Ziar Trissel LA, Saenz CA.
Compatibility screening of bivalirudin during simulated Y-site administration with other drugs.
Int J Pharm Compound 2002 ; 6: 311-315.
1721 Ziar Trissel LA, Williams KY, Baker MB.
Compatibility screening of Hextend during simulated Y-site administration with other drugs.
Int J Pharm Compound 2001 ; 5: 69-72.
1733 Ziar Kopelent-Frank H, Schimper A.
HPTLC-based stability assay for determination of amiodarone in intravenous admixtures.
Pharmazie 1999 ; 54: 542-544.
1801 Ziar Feddema S, Rusho WJ, Tyler LS, Barker B.
Physical compatibility of vasopressin with medications commonly used in cardiac arrest.
Am J Health-Syst Pharm 2003 ; 60: 1271-1272.
1803 Ziar Trissel, LA, Saenz CA, Ogundele OB, Ingram D, Baker MB.
Compatibility of fenoldopam mesylate with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2003 ; 60: 80-85.
1963 Ziar Honisko ME, Fink JM, Militello MA, Mauro VF, Alexander KS.
Compatibility of argatroban with selected cardiovascular agents.
Am J Health-Syst Pharm 2004 ; 61: 2415-2418.
2090 Ziar Pere H, Chasse V, Forest JM, Hildgen P.
Compatibility of injectable pantoprazole in Y-site administration.
Pharmactuel 2004 ; 37: 193-196.
2108 Ziar Trusley C, Kupiec TC, Trissel LA.
Compatibility of micafungin injection with other drugs during simulated Y-site co-administration.
Int J Pharm Compound 2006 ; 10: 230-232.
2109 Ziar Pelletier E, Forest JM, Hildgen P.
Compatibilité de la kétamine injectable lors de l’administration en dérivé avec d’autres médicaments usuels.
Pharmactuel 2006 ; 39: 71-75.
2139 Ziar Serrurier C, Chenot ED, Vigneron J, May I, Demor? B.
Assessment of injectable drug’s administration in two intensive care units and determination of potential physico-chemical incompatibilities.
EJHP Science 2006 ; 12,5: 96-99.
2146 Ziar Trissel LA, Xu QA, Baker M.
Drug compatibility with new polyolefin infusion solution containers.
Am J Health-Syst Pharm 2006 ; 63: 2379-2382.
2247 Ziar Chan P, Heatherly K, Kupiec T.C, Trissel L.A.
Compatibility of caspofungin acetate injection with other drugs during simulated Y-site coadministration.
Int J Pharm Compound 2008 ; 12, 3: 276-278.
2262 Ziar Brammer MK, Chan P, Heatherly K, Trusley C, Kupiec TC, Trissel LA, Psathas PA, Gilmor T, Schaufelberger D.
Compatibility of doripenem with other drugs during simulated Y-site administratioN
Am J Health-Syst Pharm 2008 ; 65: 1261-1265.
2269 Ziar Chan P, Bishop A, Kupiec TC, Trissel LA, Gole D, Jimidar IM, Vermeersch H.
Compatibility of ceftobiprole medocaril with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2008 ; 65, 16: 1545-1551.
2346 Ziar Newland A.M, Mauro V.F, Alexander K.S.
Physical compatibility of metoprolol tartrate injection with selected cardiovascular agents
Am J Health-Syst Pharm 2009 ; 66: 986-987.
3012 Ziar Sullivan T, Forrest J.M, Leclair G.
Compatibility of Cloxacillin Sodium with Selected Intravenous Drugs During Simulated Y-Site Administration
Hosp Pharm 2015 ; 50, 3: 214-220.
3134 Ziar Perez Jua En, Maqueda Palau M, Arévalo Rubert Mt, Ribas Nicolau B, Amoros Cerdà SM.
Compatibilidad visual y física de la furosemida en mezclas intravenosas para perfusión continua.
Enferm Intensiva 2010 ; 21: 96-103.
3210 Ziar Jasti Bhaskara R, Saraf Poonam.
Compatibility of Parenteral Furosemide with Seventeen Secondary Drugs Used in Standard Concentrations.
Int J Pharm Compound 2011 ; 15, 3: 259-261.
3212 Ziar Ribas Nicolau, B.; P?rez Juan, E.; Amor?s Cerd?, S.M.; Ar?valo Rubert, M.J.; Maqueda Palau, M.
Compatibilidad física del bicarbonato sódico con fármacos de uso frecuente en la unidad de cuidados intensivos.
Enferm Intensiva 2011 ;22:78-82.
3216 Ziar Legris ME, Valiquette ME, Lavoie A, Forest JM, Leclair G.
Compatibilité physique par évaluation visuelle du salbutamol injectable lors de son administration en Y.
Pharmactuel 2011 ; 44, 1 : 14-18
3249 Ziar Singh BM, Dedhiya MG, Dinunzio J, Chan P, Kupiec TC, Trissel LA, Laudano JB.
Compatibility of ceftaroline fosamil for injection with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2011 ; 68: 2163-2169.
3372 Ziar Hanci V, Ali Kiraz H, Ömür D, Ekin S, Uyan B, Yurtlu B.S.
Precipitation in Gallipoli: Sugammadex / Amiodarone & Sugammadex / Dobutamine & Sugammadex / Protamine.
Rev Bras Anestesiol 2013 ; 63, 1: 163-166.
3379 Ziar Fox L.M, Wilder A.G, Foushee J.A.
Physical compatibility of various drugs with neonatal total parenteral nutrient solution during simulated Y-site administration.
Am J Health-Syst Pharm 2013 ;70:520-524.
3381 Ziar Humbert-Delaloye V, Berger-Gryllaki M, Voirol P, Gattlen L, Pannatier A.
In vitro compatibility of various cardioactive drugs during simulated Y-site administration.
EJHP 2013 ; 20:110-116.
3408 Ziar Tollec S, Touzin K, Pelletier E, Forest J.M.
Evaluation visuelle de la compatibilité physique de la naloxone avec d’autres médicaments intraveineux usuels.
Pharmactuel 2013 ; 46, 1 : 16-21.
3463 Ziar Eva Perez Juan, Maria Jos? Arévalo Rubert , Silvia Monica Amoros Cerda , Palau M.M, Nicolau B.R.
Fármacos en perfusión continua en la unidad de cuidados intensivos: estudio de compatibilidad.
Nursing 2011 ; 29 :62-6
3464 Ziar Monica Maqueda-Palau, Eva Pérez-Juan, Maria Josep Arévalo-Rubert, Sylvia Monica Amoros-Cerda, Bàrbara Ribas-Nicolau.
Compatibilidad física de la amiodarona en perfusión continua
Enferm Clin 2011 21:25-29.
3465 Ziar E. P?rez Juan, M. Maqueda Palau, M. Ar?valo Rubert, B. Ribas Nicolau, S.M. Amor?s Cerd?.
Compatibilidad visual y física de la furosemida en mezclas intravenosas para perfusión continua.
Enferm Intensiva 2010 ;21:96-103.
3466 Ziar B. Ribas Nicolau, E. P?rez Juan, S.M. Amor?s Cerd?, M.J. Ar?valo Rubert, M. Maqueda Palau.
Compatibilidad física del bicarbonato sódico con fármacos de uso frecuente en la unidad de cuidados intensivos
Enferm Intensiva 2011 ;22:78-82.
3524 Laborator Amiodarone hydrochloride (Cordarone®) - Summary of Product Characteristics.
Sanofi 2013
3539 Laborator Bivalirudin (Angiox®) - Summary of Product Characteristics.
The Medecines Company 2013
3540 Laborator Heparin sodium - Summary of Product Characteristics.
Wockhardt 2010
3766 Ziar Forrest J.M, Hildgen P.
Compatibilité de l’acétylcystéine injectable lors de son administration en Y avec d’autres médicaments usuels
Pharmactuel 2014 ; 47, 3 : 161-165.
3767 Ziar Legris M.E, Lavoie A, Forrest J.M, Hildgen P.
Compatibilité par évaluation visuelle du thiopental injectable lors de son administration en Y avec des médicaments usuels.
Pharmactuel 2014 ; 47, 3 : 167-172.
3823 Ziar Juan E.P, Palau M.M, Cerd? S.A, Rubert M.A, Nicolau B.R.
Compatibilité physique de médicaments administrés dans l’unité de soins intensifs
Pharmactuel 2015 ; 48, 3 : 146-152.
3824 Ziar Boudi S, Roy H, Forest JM, Leclair G.
Compatibilité physique de l'association amoxicilline-acide clavulanique en injection avec plusieurs autres médicaments lors d'une administration en Y.
Pharmactuel 2023 2023;56,3:91-98
3827 Poster Ghazi I.M, Hamada Y, Nicolau D.P.
Compatibility of tedizolid phosphate with selected intravenous drugs via simulated Y-site conditions.
ASHP Midyear 2015
3828 Poster Thabit A.K, Hamada Y, Nicolau D.P.
Ceftozolane/tazobactam physical compatibility during simulated Y-site administration.
ASHP Midyear 2015
3829 Poster So W, Kim L, Thabit A.K, Nicolau D.P, Kuti J.L.
Compatibility of isavunazonium sulfate during simulated Y-site administration.
ASHP Midyear 2015
3932 Laborator Hydroxocobalamine (Cyanokit®) - Résumé des caractéristiques du produit
Serb Laboratoire 2015
3964 Ziar Audet M.A, Forest E, Friciu M, Forest J.M, Leclair G.
Compatibilité du citrate de caféine injectable avec plusieurs autres médicaments.
Pharmactuel 2017 ; 50,1 : 27-33.
4055 Ziar Monogue M, Almarzoky Abuhussain S, Kuti J, Nicolau D.
Physical compatibility of fosfomycin for injection with select i.v. drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2018 , 75, 1:36-44
4119 Poster Marcoz N, Ing H, Sautter AM, Saadi JF, Roulin JF, Bonnabry P.
Stabilité et compatibilité de solutions injectables d'amiodarone (Cordarone®)
Hôpitaux Universitaire de Genève 2004
4130 Ziar Koller AK, Krebs S, Dörje F.
Untersuchungen zur Kompatibilität von Clonidin mit häufig eingesetzen Arzneimittel auf Intensivstationen.
Pharmaceutics 2021 , 13, 21.
4145 Ziar Asempa T.E, Avery L.M, Kidd J.M, Kuti J.L, Nicolau D.P.
Physical compatibility of plazomicin with select i.v. drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2018 ;75,14:1048-1056
4252 Ziar Lardinois B, Dimitriou A, Delcave C, Jamart J, Bihin B, Soumoy L, Hecq JD, Galanti LM.
Evaluation of the Physicochemical Stability of Amiodarone Hydrochloride in Syringes for the Intensive Care Unit.
Int J Pharm Compound 2019 ;23,2:163-166
4319 Ziar Lessard J-J, Caron E, Schérer H, Forest J-M, Leclair G.
Compatibility of Y-site Injection of Meropenem Trihydrate With 101 Other Injectable Drugs.
Hosp Pharm 2020 ; 55, 5: 332-337.
4354 Poster Sicard G, Donnette M, Martin N, Gensollen S, Pourroy B, Fanciullino R.
Compatibilité visuelle du Vyxeos lors d'administration en Y avec une sélection de médicaments injectables.
GERPAC Congress 2019 2019
4371 Ziar Mediavilla MM, Molina A, Navarro L, Grau L, Pujol MD, Cardenete J, Cardona D, Riera P.
Physicochemical Compatibility of Amiodarone with Parenteral Nutrition.
Journal of Parenteral and Enteral Nutrition 2018
4411 Ziar Wilder A.G, Foushee J.A, Fox L.M, Navalle J, Wright A.M, Greer M.A.
Physical Compatibility of Medications Used in Critically Ill Patients with Balanced Fluid Solutions.
Int J Pharm Compound 2020 ;24,3:238-241.
4434 Ziar Avery L.M, Chen, I.H, Reyes, S, Nicolau, D.P, Kuti J.L.
Assessment of the Physical Compatibility of Eravacycline and Common Parenteral Drugs During Simulated Y-site Administration.
Clin Ther 2019 ; 41, 10: 2162-2170.
4491 Ziar De Basagoiti A, Katsumiti A, Abascal S, Bustinza A, López-Giménez L.R, Pilar P, De Miguel M, Campino A.
Physical compatibility of alprostadil with selected drugs commonly used in the neonatal intensive care units.
Eur J Pedia 2020
4506 Ziar Griffith S, Stapleton E, Padilla S, Mruk A, Thomas C.
Physical compatibility of milrinone 1 mg/mL with select cardiovascular medications during simulated Y-site administration.
Am J Health-Syst Pharm 2020 ;77,23:1938-1940.
4528 Ziar Lu J, Liu Q, Kupiec T, Vail H, Lunch L, Fam D, Vu N.
Physical Compatibility of Cefiderocol with Selected Intravenous Drugs During Simulated Y-site Administration.
Int J Pharm Compound 2021 ;25,1:52-61
4603 Ziar Vallée M, Barthélémy I, Friciu M, Pelletier E, Forest J.M, Benoit F, Leclair G.
Compatibility of Lactated Ringer’s Injection With 94 Selected Intravenous Drugs During Simulated Y-site Administration.
Hosp Pharm 2021 ; 56, 4: 228-234.
4650 Laborator Ceftobiprole (Zevtera 500 mg powder for concentrate for solution for infusion.) Summary of Product Characteristics, Advanz Pharma updated 4 aug 2021.
Advanz Pharma 2021
4651 Ziar De Basagoiti A, Katsumiti A, Abascal S, Bustinza A, López-Giménez L.R, Pascual P, De Miguel M, Campino A.
Physical compatibility of alprostadil with selected drugs commonly used in the neonatal intensive care units.
Eur J Pedia 2021 ;180,1169–1176.
4655 Ziar Holyk A, Lindner A, Lindner S, Shippert B
Physical compatibility of Normosol-R with critical care medications used in patients with COVID-19 during simulated Y-site administration.
Am J Health-Syst Pharm 2022 ;79,1:27-33
4698 Ziar Ayari G, D'Huart E, Vigneron J, Demoré B.
Y-site compatibility of intravenous medications commonly used in intensive care units : laboratory tests on 75 mixtures involving nine main drugs.
Pharmaceutical Technology in Hospital Pharmacy 2022
4742 Ziar Macoviciuc M, Nguyen C, Forest J-M, Leclair G.
Compatibilité physique de l’acétaminophène injectable avec 102 autres médicaments lors d’une administration en Y.
Pharmactuel 2022 ; 55, 4: 247-255.

  Mentions Légales