Ultimele actualizari :
03/05/2024
Diverse   Oxytocin  
Injectabil
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie Pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Evatocin India
Foetocin India
Genox India
Gynotocin India
Hipofisina Argentina
Hipracin Suedia
Ocitocina Argentina
Orasthin Germania
Ossitocina Italia
Oxitocina Argentina, Chilli, Columbia, Ecuador, Peru, Portugalia, Spania, Venezuela
Oxitomek Peru
Oxitopisa Columbia, Mexic
Oxycinon Egipt
Oxyla Malaezia
Oxytip Iran
Oxytocin Canada, Egipt, Germania, Grecia, Iran, Malaezia, Polonia, Romania, SUA, Ungaria
Oxytocine Tunisia
Pitocin Ecuador, SUA
Postuitrin Turcia
Synpitan Turcia
Syntocinon Argentina, Australia, Austria, Belgia, Chilli, Columbia, Danemarca, Egipt, Elvetia, Emiratele Arabe Unite, Finlanda, Franta, Irlanda, Islanda, Italia, Luxemburg, Malaezia, Marea Britanie, Maroc, Mexic, Noua Zeelandă, Olanda, Peru, Portugalia, Spania, Suedia, Tunisia, Venezuela
Udoxan Malaezia
Veracuril Argentina
Xitocin Mexic
Zetocin India
Bibliografie   Injectabil   Bibliografie : Oxytocin  
Tip Publicare
129 Ziar Smythe M, Malouf E.
Visual compatibility of insulin with secondary intravenous drugs in admixtures.
Am J Hosp Pharm 1991 ; 48: 125-126.
406 Ziar Smythe MA, Patel MA, Gasloli RA.
Visual compatibility of narcotic analgesics with selected intravenous admixtures.
Am J Hosp Pharm 1990 ; 47: 819-820.
552 Ziar Martinez JF, Trissel LA, Gilbert DL.
Compatibility of warfarin sodium with selected drugs and large-volume parenteral solutions.
Int J Pharm Compound 1997 ; 1: 356-358.
1057 Ziar Cutie MR.
Compatibility of verapamil hydrochloride injection with commonly used additives.
Am J Hosp Pharm 1983 ; 40: 1205-1207.
1200 Ziar Chaudry IA, Bruey KP, Hurlburt LE, Oden EM.
Compatibility of netilmycin sulfate injection with commonly used intravenous injections and additives.
Am J Hosp Pharm 1981 ; 38: 1737-1742.
1228 Ziar Allen LV, Stiles ML.
Compatibility of various admixtures at Y-injection sites of intravenous administration sets. Part2.
Am J Hosp Pharm 1981 ; 38: 380-381.
1725 Ziar Oliver C, Law S.
Compatibility of oxytocin, zidovudine, and penicillin G.
Can J Hosp Pharm 2001 ; 54: 112-113.
1903 Ziar Gard JW, Alexander JM, Bawdon RE, Albrecht JT.
Oxytocin preparation stability in several common obstetric intravenous solutions.
Am J Obstet Gynecol 2002 ; 186: 496-498.
1926 Ziar Anderson PL, Miller S, Bushman LR.
Stability of zidovudine with oxytocin in a simulated Y-site injection.
Am J Health-Syst Pharm 2004 ; 61: 394-396.
2087 Ziar Ferreira E, Forest JM, Hildgen P.
Compatibility of dimenhydrinate injectable by Y administration.
Pharmactuel 2004 ; 37: 17-20.
2090 Ziar Pere H, Chasse V, Forest JM, Hildgen P.
Compatibility of injectable pantoprazole in Y-site administration.
Pharmactuel 2004 ; 37: 193-196.
2097 Ziar Trissel LA, Zhang Y, Douglass K, Kastango E.
Extended stability of oxytocin in common infusion solutions.
Int J Pharm Compound 2006 ; 10: 156-158.
2109 Ziar Pelletier E, Forest JM, Hildgen P.
Compatibilité de la kétamine injectable lors de l’administration en dérivé avec d’autres médicaments usuels.
Pharmactuel 2006 ; 39: 71-75.
2165 Ziar Kumar V, Madabushi R, Derendorf H, Boothby LA, Breland BD, Hatton RC, Doering PL.
Development and validation of an HPLC method for oxytocin in Ringer’s lactate and its application in stability analysis.
J Liquid Chrom Rel Technol 2006 ; 29, 16: 2353-2365.
3012 Ziar Sullivan T, Forrest J.M, Leclair G.
Compatibility of Cloxacillin Sodium with Selected Intravenous Drugs During Simulated Y-Site Administration
Hosp Pharm 2015 ; 50, 3: 214-220.
3216 Ziar Legris ME, Valiquette ME, Lavoie A, Forest JM, Leclair G.
Compatibilité physique par évaluation visuelle du salbutamol injectable lors de son administration en Y.
Pharmactuel 2011 ; 44, 1 : 14-18
3347 Ziar Kaushal, G., Sayre, B.E., Prettyman, T.
Stability-indicating HPLC method for the determination of the stability of oxytocin parenteral solutions prepared in polyolefin bags.
Drug Discov Ther 2012 ; 6, 1 : 49-54.
3372 Ziar Hanci V, Ali Kiraz H, Ömür D, Ekin S, Uyan B, Yurtlu B.S.
Precipitation in Gallipoli: Sugammadex / Amiodarone & Sugammadex / Dobutamine & Sugammadex / Protamine.
Rev Bras Anestesiol 2013 ; 63, 1: 163-166.
3408 Ziar Tollec S, Touzin K, Pelletier E, Forest J.M.
Evaluation visuelle de la compatibilité physique de la naloxone avec d’autres médicaments intraveineux usuels.
Pharmactuel 2013 ; 46, 1 : 16-21.
3767 Ziar Legris M.E, Lavoie A, Forrest J.M, Hildgen P.
Compatibilité par évaluation visuelle du thiopental injectable lors de son administration en Y avec des médicaments usuels.
Pharmactuel 2014 ; 47, 3 : 167-172.
3824 Ziar Boudi S, Roy H, Forest JM, Leclair G.
Compatibilité physique de l'association amoxicilline-acide clavulanique en injection avec plusieurs autres médicaments lors d'une administration en Y.
Pharmactuel 2023 2023;56,3:91-98
3964 Ziar Audet M.A, Forest E, Friciu M, Forest J.M, Leclair G.
Compatibilité du citrate de caféine injectable avec plusieurs autres médicaments.
Pharmactuel 2017 ; 50,1 : 27-33.
4319 Ziar Lessard J-J, Caron E, Schérer H, Forest J-M, Leclair G.
Compatibility of Y-site Injection of Meropenem Trihydrate With 101 Other Injectable Drugs.
Hosp Pharm 2020 ; 55, 5: 332-337.
4389 Ziar Côté K, Correal F, Metras M.E, Friciu M, Forest J.M, Leclair G.
Compatibilité physique des médicaments administrés en Y aux soins intensifs, en particulier la dexmédétomidine, le lévosimendan et la kétamine.
Pharmactuel 2019 ;52,4:206-213
4603 Ziar Vallée M, Barthélémy I, Friciu M, Pelletier E, Forest J.M, Benoit F, Leclair G.
Compatibility of Lactated Ringer’s Injection With 94 Selected Intravenous Drugs During Simulated Y-site Administration.
Hosp Pharm 2021 ; 56, 4: 228-234.

  Mentions Légales