Ultimele actualizari :
08/05/2024
Citostatic   Epirubicin hydrochloride  
Injectabil
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie Pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Anthracine Malaezia
Axirubicine Germania
Bendaepi Germania
Binarin Mexic
Bioepycina Polonia
Crisabon Argentina
Cuatroepi Argentina
Ecclepia Romania
Elebicin Mexic
Ellence SUA
Epi Cell Germania
Epidoxo Argentina, Chilli, Venezuela
Epifil Ecuador
Epilem Columbia, Mexic
Epimedac Germania
Epirubicin Arabia Saudita, Australia, Austria, Belgia, Danemarca, Elvetia, Islanda, Marea Britanie, Noua Zeelandă, Suedia, Turcia, Ungaria
Epirubicina Argentina, Columbia, Ecuador, Mexic, Romania, Spania
Epirubicine Belgia, Elvetia, Franta
Farmarubicin Turcia
Farmorubicin Arabia Saudita, Austria, Brazilia, Danemarca, Elvetia, Finlanda, Grecia, Norvegia, Suedia
Farmorubicin CSV Africa de Sud
Farmorubicin PFS Croatia, Polonia, Slovenia
Farmorubicin RD Brazilia, Elvetia, Polonia, Rusa
Farmorubicin RTU Olanda
Farmorubicina Brazilia, Italia, Portugalia, Spania
Farmorubicine Belgia, Franta
Pharmorubicin Marea Britanie
Bibliografie   Injectabil   Bibliografie : Epirubicin hydrochloride  
Tip Publicare
148 Ziar Dine T, Cazin JC, Gressier B, Luycks M, Brunet C, Cazin M, Goudaliez F, Mallevais ML, Toraub I.
Stability and compatibility of four anthracyclines: doxorubicin, epirubicin, daunorubicin and pirarubicin with PVC infusion bags.
Pharm Weekbl [Sci] 1992 ; 14: 365-369.
525 Ziar De Vroe C, De Muynck C, Remon JP, Samsom M.
A study on the stability of three antineoplastic drugs and on their sorption by IV delivery systems and end-line filters.
Int J Pharm 1990 ; 65: 49-56.
683 Ziar Walker SE, Lau DWC, DeAngelis C, Iazetta J, Coons C.
Epirubicin stability in syringes and glass vials and evaluation of chemical contamination.
Can J Hosp Pharm 1990 ; 43: 265-272.
686 Ziar Wood MJ, Irwin WJ, Scott DK.
Stability of doxorubicin, daunorubicin and epirubicin in plastic syringes and minibags.
J Clin Pharm Ther 1990 ; 15: 279-289.
887 Ziar Pujol M, Munoz M, Prat J, Giona V, De Bolos J.
Stability study of epirubicin in NaCl 0.9% injection.
Ann Pharmacotherapy 1997 ; 31: 992-995.
1237 Ziar Keusters L, Stolk LML, Umans R, Van Asten P.
Stability of solutions of doxorubicin and epirubicin in plastic minibags for intravesical use after storage at -20°C and thawing by microwave radiation.
Pharm Weekbl [Sci] 1986 ; 8: 194-197.
1265 Ziar Wood MJ, Irwin WJ, Scott DK.
Photodegradation of doxorubicin, daunorubicin and epirubicin measured by high-performance liquid chromatography.
J Clin Pharm Ther 1990 ; 15: 291-300.
1317 Ziar Adams PS, Haines-Hutt RF, Bradford E, Palmer A, Rowland CG.
Pharmaceutical aspects of home infusion therapy for cancer patients.
Pharm J 1987 ; 238: 476-478.
1662 Ziar Trissel LA, Saenz CA, Ingram DS, Ogundele AB.
Compatibility screening of oxaliplatin during simulated Y-site administration with other drugs.
J Oncol Pharm Practice 2002 ; 8: 33-37.
1823 Ziar Sewell GJ, Rigby-Jones AE, Priston MJ.
Stability of intravesical epirubicin infusion: a sequential temperature study.
J Clin Pharm Ther 2003 ; 28: 349-353.
1897 Ziar Sautou-Miranda V, Brigas F, Thibault M, Chopineau J.
Compatibility of doxorubicin, daunorubicin and epirubicin with low-density polyethylene and polyvinyl chloride, and stability in various conditions of storage.
EJHP 2001 ; 7, 3: 108-115.
1955 Ziar Trissel LA, Zhang Y.
Palonosetron HCl compatibility and stability with doxorubicin HCl and epirubicin HCl during simulated Y-site administration.
Ann Pharmacotherapy 2005 ; 39: 280-283.
2168 Ziar Ozdemir FA, Anilanmert B, Pekin M.
Spectrophotometric investigation of the chemical compatibility of the anticancer irinotecan-HCl and epirubicin-HCl in the same infusion solution.
Cancer Chemother Pharmacol 2005 ; 56, 5: 529-534.
2257 Laborator Stability of epirubicin "Ebewe" infusion solutions.
Ebewe Pharma 2007
3473 Ziar Bennis Y, Savry A, Correard F, Montana M, Sauzet C, Gauthier-Villano L, Pisano P, Pourroy B.
Stability of a highly concentrated solution of epirubicin for conventional transcatheter arterial chemoembolization.
Int J Pharm 2015 ; 495, 2: 956-962.
3474 Laborator Fluorouracil - Summary of Product Characteristics
Accord Healthcare Limited 2009
3632 Laborator Epirubicine (Epirubicine Hospira®) - Summary of Product Characteristics
Hospira 2017
3670 Ziar Sewell G, Massimini M.
Studies on the stability and compatibility of cytotoxic drug infusion with the Tevadaptor system.
EJOP 2014 ; 8, 3: 26-30.
3708 Poster Sarakbi I, Thiesen J, Krämer I.
Compatibility of epirubicin-loaded DC Beads with different contrast media.
ECOP 2 Krakow 2014
3918 Ziar Sarakbi I, Krämer I.
Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media.
J Oncol Pharm Practice 2016 ; 22: 749-756.
4352 Ziar Li J, Yao C, Xu Y, Ping P, Yin H, Sun Y.
In vitro compatibility and stability of admixtures containing etoposide, epirubicin hydrochloride and vindesine sulphate in a single infusion bag.
J Clin Pharm Ther 2019 ; 44: 875-882.

  Mentions Légales