Last update :
28/04/2024
References   References 306  
Type : Journal
Web link : http://www.ajhp.org/cgi/content/abstract/53/2/170

Research teams : Ann Arbor - University of Michigan, College of Pharmacy
Authors : Christen C, Johnson CE, Walters JR.
Title : Stability of bupivacaine hydrochloride and hydromorphone hydrochloride during simulated epidural coadministration.
Reference : Am J Health-Syst Pharm ; 53: 170-173. 1996

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
InjectionBupivacaine hydrochloride Local anesthetic
Compatible 0,625 & 1,25 mg/ml + InjectionHydromorphone hydrochloride 0,02 & 0,1 mg/ml + Sodium chloride 0,9%
InjectionHydromorphone hydrochloride Analgesic
Compatible 0,02 & 0,1 mg/ml + InjectionBupivacaine hydrochloride 0,625 & 1,25 mg/ml + Sodium chloride 0,9%
Stability of mixtures
Polyvinyl chloride Sodium chloride 0,9% 23°C-25°C Light
Injection Bupivacaine hydrochloride 0,62 & 1,2 mg/ml
Injection Hydromorphone hydrochloride 0,02 & 0,1 mg/ml
72 Hour