Last update :
17/09/2021
Anticancer drug   Mitomycin  
Injection
Stability in solutions Stability of mixtures Factors which affect stability Compatibility Route of administration References Pdf
   Chemical structure  

Tradename   Tradename     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Ametycine France
Crisofimina Argentina
Fatrix Chile
Mitem Germany
Mitocin Brazil
Mitokebir Argentina
Mitomicina Argentina, Ecuador, Portugal, Romania
Mitomycin Austria, Belgium, Denmark, Germany, Great Britain, Hungary, Ireland, Italy, Malaysia, Poland
Mutamycin United States of America
Stability in solutions   Injection   Stability in solutions : Mitomycin     
Container Solvent Concentration Temperature Storage Length of time References
Glass Water for Injection 1 mg/ml 25°C Not specified
24 Hour
1827
Level of evidence A

Conflicting data
Glass Water for Injection 1 mg/ml 25°C Protect from light
8 Hour
3897
Level of evidence B

Conflicting data
Polyvinyl chloride Sodium chloride 0,9% 0.6 mg/ml -30°C Protect from light
30 Day
1239
Level of evidence D

Not specified Water for Injection 0,4 mg/ml -20°C Not specified
23 Day
4367
Level of evidence C

Not specified Water for Injection 0,4 mg/ml 25°C Not specified
24 Hour
4367
Level of evidence C

Not specified Water for Injection 0,4 mg/ml 4°C Not specified
14 Day
4367
Level of evidence C

Not specified Water for Injection 0,6 mg/ml 4°C Protect from light
4 Day
1827
Level of evidence A

Not specified Water for Injection 0,6 & 0,8 mg/ml 25°C Protect from light
4 Day
1827
Level of evidence A

Conflicting data
Polypropylen Syringe Water for Injection 0,5 mg/ml 25°C Protect from light
7 Day
648
Level of evidence D

Conflicting data
Polypropylen Syringe Water for Injection 0,5 mg/ml 4°C Protect from light
28 Day
648
Level of evidence D

Polypropylen Syringe Water for Injection 1 mg/ml 25°C Protect from light
8 Hour
3897
Level of evidence B

Conflicting data
Polypropylen Syringe Sodium chloride 0,9% 0,2 mg/ml 25°C Protect from light
10 Hour
3897
Level of evidence B

Conflicting data
Polypropylen Syringe Sodium chloride 0,9% 1 mg/ml 37°C Not specified
5 Hour
4282
Polypropylen Syringe Sodium chloride 0,9% 2 mg/ml 37°C Not specified
5 Hour
4282

  Mentions Légales