Last update :
08/05/2024
Anticancer drug   Oxaliplatin  
Injection
Stability in solutions Stability of mixtures Factors which affect stability Compatibility Route of administration References Pdf
   Chemical structure  

Tradename   Tradename     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Axiplatin Germany
Bendaplatin Germany
Bioezulen Brazil
Celdach Peru
Crisapla Chile, Ecuador, Venezuela
Crisatinox Turkey
Dabenzol Argentina, Ecuador
Dacplat Argentina
Eloxarin Ecuador
Eloxatin Austria, Belgium, Brazil, Chile, Colombia, Egypt, Great Britain, Iran, Italy, Luxembourg, Malaysia, Mexico, New Zealand, Norway, Peru, Portugal, Romania, Spain, Sweden, Switzerland, Thailand, Turkey, United Arab Emirates, United States of America, Venezuela
Eloxatine France, Morocco, Switzerland
Entia Colombia, Mexico
Euroxaliplatine Germany
Glenoxal Peru
Goxyral Argentina, Ecuador
Kebir Argentina, Peru
Linoxa Turkey
Lisix Chile
Metaplatin Argentina
Oliptino Argentina
Onicol Chile, Peru
Oxalibbs Brazil
Oxaliplan Germany
Riboxatin Germany
References   Injection   References : Oxaliplatin  
Type Publication
1662 Journal Trissel LA, Saenz CA, Ingram DS, Ogundele AB.
Compatibility screening of oxaliplatin during simulated Y-site administration with other drugs.
J Oncol Pharm Practice 2002 ; 8: 33-37.
1950 Journal Trissel LA, Yanping Z.
Physical and chemical stability of palonosetron HCl with cisplatin, carboplatin and oxaliplatin during simulated Y-site administration.
J Oncol Pharm Practice 2004 ; 10: 191-195.
2207 Journal André A, Cisternino S, Roy A.L, Chiadmi F, Schlatter J, Agranat P, Fain O, Fontan J.E.
Stability of oxaliplatin in infusion bags containing 5% dextrose injection.
Am J Health-Syst Pharm 2007 ; 64, 18: 1950-1954.
2239 Journal Wang C, Zhang X, Liu HY.
Determination of the stability of oxaliplatin for injection by dual wavelength spectrophotometry.
Chinese J New Drugs 2005 ; 14, 2: 189-191.
2253 Journal Curis E, Provost K, Bouvet D, Nicolis I, Crauste-manciet S, Brossard D, B?nazeth S.
Carboplatin and oxaliplatin decomposition in chloride medium, monitored by XAS.
J Synchrotron Rad 2001 ; 8: 716-718.
2258 Manufacturer Stability of oxaliplatin "Ebewe" lyophilisate after reconstitution.
Ebewe Pharma 2007
2259 Manufacturer Stability of oxaliplatin "Ebewe" lyophilisate infusion solutions.
Ebewe Pharma 2007
2321 Journal Junker A, Roy S, Desroches M.C, Moussay C, Berhoune M, Bellanger A, Fernandez C,Farinotti R.
Stability of Oxaliplatin Solution.
Ann Pharmacotherapy 2009 ; 43,2: 390-391.
2791 Journal Mehta A.M,.Van den Hoven J.M, Rosing H,.Hillebrand M.J.X, Nuijen B,. Huitema A.D.R, Beijnen J.H,.Verwaal V.J.
Stability of oxaliplatin in chloride-containing carrier solutions used in hyperthermic intraperitoneal chemotherapy.
Int J Pharm 2015 ; 479 : 23-27.
2883 Journal Eiden C, Philibert L, Bekhtari K, Poujol S, Malosse F, Fr?d?ric Pinguet F.
Physicochemical stability of oxaliplatin in 5% dextrose injection stored in polyvinyl chloride, polyethylene, and polypropylene infusion bags.
Am J Health-Syst Pharm 2009 ; 66, 21: 1929-1933.
3369 Manufacturer Levofolinate de sodium Medac - Résumé des caractéristiques du produits
MEDAC France 2011
3413 Journal Jerremalm E, Hedeland M, Wallin I, Bondesson U, Ehrsson H.
Oxaliplatin degradation in the presence of chloride: Identification and cytotoxicity of the monochloro monooxalato complex.
Pharm Res 2004 ; 21, 5: 891-894.
3602 Manufacturer Mesna (Uromitexan®)- Summary of Product Characteristics
Baxter SAS 2013
3634 Manufacturer Oxaliplatine (Oxaliplatine Accord®) - Résumé des caractéristiques du produit
Accord Healthcare 2011
3670 Journal Sewell G, Massimini M.
Studies on the stability and compatibility of cytotoxic drug infusion with the Tevadaptor system.
EJOP 2014 ; 8, 3: 26-30.
3706 Journal Escudero-Ortiz V, Duart-Duart M.J, P?rez-Ruixo C, P?rez-Ruixo J.J, Valenzuela B.
Estudio de estabilidad de oxaliplatino y doxorrubicina para su administración intraperitoneal con hipertermia.
Farm Hosp 2014 ;38, 3:154-161
4004 Journal Krämer I, Sarakbi I, Thiesen J, Mainz.
Physikalisch-chemische Stabilität von Oxaliplatin-beta-Infusionslösungskonzentrat und Infusionslösungen in 5 % Glucose in Polyolefin-Infusionsbeuteln.
Krankenhauspharmazie 2017 ;38,7:334?340.

  Mentions Légales