Last update :
18/04/2024
References   References 645  
Type : Journal PC : 0.0006830601092896 

Research teams : Exeter - University of Exeter
Authors : Sewell GJ, Riley CM, Rowland CG.
Title : The stability of carboplatin in ambulatory continuous infusion regimes.
Reference : J Clin Pharm Ther ; 12: 427-432. 1987

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
Comments : 
No comments for the degradation products

List of drugs
InjectionCarboplatin Anticancer drug
Stability in solutions Polypropylen Syringe Water for Injection 10 mg/ml 37°C Protect from light
24 Hour
Stability in solutions Polypropylen Syringe Water for Injection 10 mg/ml 4°C Protect from light
120 Hour

  Mentions Légales