Last update :
18/04/2024
References   References 4725  
Type : Journal

Research teams : Grenade - Faculty of Science, Department of Analytical Chemistry
Authors : Perez-Robles R, Hermosilla J, Navas N, Clemente-Batuista S, Jimenez-Lozano I, Cabanas-Poy MJ, Ruiz-Trave J et al.
Title : Tracking the physicochemical stability of teduglutide (Revestive®) clinical solutions over time in different storage containers.
Reference : J Pharm Biomed Anal 2022

Level of Evidence : 
Level of evidence A+
Physical stability : 
Size Exclusion Chromatography Protein: Dynamic Light Scattering 
Chemical stability : 
Protein: Peptide mapping
Other methods : 
PH measurement 
Comments : 

List of drugs
InjectionTeduglutide Various
Stability in solutions Glass Water for Injection 10 mg/ml 4-8°C Protect from light
7 Day
Stability in solutions Polypropylen Syringe Water for Injection 10 mg/ml -20°C Protect from light
45 Day
Stability in solutions Polypropylen Syringe Water for Injection 10 mg/ml 4-8°C Protect from light
28 Day