Last update :
18/04/2024
References   References 4341  
Type : Journal
Web link : https://ijpc.com/Abstracts/Abstract.cfm?ABS=4667

Research teams : Amsterdam - Academic Medical center, Department of Pharmacy
Authors : Van der Schaar JAJ, Grouls R, Franssen EJF, Crul M.
Title : Stability of Furosemide 5 mg/mL in Polypropylene Syringes.
Reference : Int J Pharm Compound ;23,5:414-417 2019

Level of Evidence : 
Level of evidence A
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
InjectionFurosemide Diuretic
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 5 mg/ml 20°C Light
24 Hour
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 5 mg/ml 4°C Protect from light
35 Day

  Mentions Légales