Last update :
18/04/2024
References   References 4109  
Type : Journal

Research teams : Hobart - University of Tasmania, School of Pharmacy
Authors : Madfai F, Zaidi S, Ming L, Wanandy T, Patel R.
Title : Stability of milrinone in continuous ambulatory delivery devices.
Reference : Am J Health-Syst Pharm ;75,9:241-245 2018

Level of Evidence : 
Level of evidence A+
Physical stability : 
Visual examination Microscopic examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
InjectionMilrinone lactate Cardiotonic
Stability in solutions Not specified NaCl 0,9% or Glucose 5% 0,6 mg/ml 25°C Not specified
24 Hour
Stability in solutions Not specified NaCl 0,9% or Glucose 5% 0,6 mg/ml 35°C Not specified
24 Hour
Stability in solutions Not specified NaCl 0,9% or Glucose 5% 0,6 mg/ml 4°C Not specified
7 Day