Last update :
28/04/2024
References   References 3537  
Type : Journal
Web link : http://www.krankenhauspharmazie.de/archiv/verzeichnis/2013/11.html

Research teams : Tubingen - University Hospital Tübingen, Department of Pharmacy
Authors : Lipp HP, Gfrörer W, Riedmüller S.
Title : Bortezomib zur subkutanen Applikation.
Reference : Krankenhauspharmazie ; 34,11: 500-505. 2013

Level of Evidence : 
Level of evidence D
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
Comments : 
Stability indicating capability inadequately assessed
Repeatability / reproducibility / standard range: results not provided or results outside specified values
Results with high coefficient of variation or not provided, or lack of duplicate analysis of each point
No comments for the degradation products
No visual inspection

List of drugs
InjectionBortezomib Anticancer drug
Stability in solutions Glass Sodium chloride 0,9% 2.5 mg/ml 2-8°C Not specified
14 Day
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 2.5 mg/ml 2-8°C Not specified
14 Day