Last update :
03/05/2024
References   References 3486  
Type : Journal
Web link : http://link.springer.com/article/10.1007/s00270-012-0429-6

Research teams : Charleroi - CHU de Charleroi, Department of Radiology
Authors : Delcour C, Brunnix G.
Title : Incompatibility of contrast medium and trisodium citrate.
Reference : Cardiovasc Intervent Radiol ; 36: 237-238. 2013

Level of Evidence : 
Physical stability : 
Chemical stability : 
Other methods : 
Comments : 

List of drugs
InjectionIobitridol Radiocontrast agent
Incompatible 350 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionIodixanol Radiocontrast agent
Incompatible 270 & 320 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionIohexol Radiocontrast agent
Incompatible 240 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionIomeprol Radiocontrast agent
Incompatible 400 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionIopromide Radiocontrast agent
Incompatible 370 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionIoxaglate Radiocontrast agent
Incompatible 320 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionIoxitalamate sodium Radiocontrast agent
Incompatible 120 & 350 mg I/ml + InjectionTrisodium citrate 467 mg/ml + None
InjectionTrisodium citrate Various
Incompatible 467 mg/ml + InjectionIobitridol 350 mg I/ml + None
Incompatible 467 mg/ml + InjectionIodixanol 270 & 320 mg I/ml + None
Incompatible 467 mg/ml + InjectionIohexol 240 mg I/ml + None
Incompatible 467 mg/ml + InjectionIomeprol 400 mg I/ml + None
Incompatible 467 mg/ml + InjectionIopromide 370 mg I/ml + None
Incompatible 467 mg/ml + InjectionIoxaglate 320 mg I/ml + None
Incompatible 467 mg/ml + InjectionIoxitalamate sodium 120 & 350 mg I/ml + None