Last update :
28/04/2024
References   References 2366  
Type : Poster
Icone.pdf
178Ko

Research teams : Fribourg - University Hospital Freiburg, Department of Pharmacy
Authors : M?ller S, Trittler R, Schubert R.
Title : Oxycodon-Metamizol in PCA pumpen : Kompatibel?
Reference : ADKA Congress 2009

Level of Evidence : 
Physical stability : 
Chemical stability : 
Other methods : 
Comments : 

List of drugs
InjectionMetamizol sodium Analgesic
InjectionOxycodone hydrochloride Analgesic
Stability of mixtures
Polyvinyl chloride Sodium chloride 0,9% 2-8°C Protect from light
Injection Oxycodone hydrochloride 0,4 >> 30 mg/ml
Injection Metamizol sodium 66,7 >> 83 mg/ml
10 Day
Polyvinyl chloride Sodium chloride 0,9% 2-8°C Protect from light
Injection Oxycodone hydrochloride 40 mg/ml
Injection Metamizol sodium 66,7 >> 83 mg/ml
21 Day
Polyvinyl chloride Sodium chloride 0,9% 25°C Not specified
Injection Oxycodone hydrochloride 40 mg/ml
Injection Metamizol sodium 66,7 >> 83 mg/ml
4 Day
Polyvinyl chloride Sodium chloride 0,9% 25°C Not specified
Injection Oxycodone hydrochloride 0,4 >> 10 mg/ml
Injection Metamizol sodium 66,7 >> 83 mg/ml
24 Hour
Polyvinyl chloride Sodium chloride 0,9% 25°C Not specified
Injection Oxycodone hydrochloride 10 >> 30 mg/ml
Injection Metamizol sodium 66,7 >> 83 mg/ml
48 Hour