Last update :
28/04/2024
References   References 2147  
Type : Journal
Web link : https://doi.org/10.1345/aph.1G321

Research teams : Albany - Albany College of Pharmacy, Department of Pharmaceutical Sciences
Authors : Nornoo AO, Elwell RJ.
Title : Stability of vancomycin in icodextrin peritoneal dialysis solution.
Reference : Ann Pharmacotherapy ; 40, 11: 1950-1954. 2006

Level of Evidence : 
Level of evidence D
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
Stability defined as 90% of the initial concentration
Other methods : 
PH measurement 
Comments : 
Stability indicating capability inadequately assessed
No comments for the degradation products

List of drugs
InjectionVancomycin hydrochloride Antibiotic
Stability in solutions Polyvinyl chloride Extraneal® (Baxter) 0.94 mg/ml 24°C Protect from light
7 Day
Stability in solutions Polyvinyl chloride Extraneal® (Baxter) 0.94 mg/ml 37°C Protect from light
24 Hour
Stability in solutions Polyvinyl chloride Extraneal® (Baxter) 0.94 mg/ml 5°C Protect from light
7 Day