Last update :
03/05/2024
References   References 179  
Type : Journal
Web link : http://www.ajhp.org/cgi/content/abstract/49/6/1471

Research teams : Oklahoma City - University of Oklahoma Health Sciences Center, College of Pharmacy
Authors : Stiles ML, Allen LV Jr, Fox JL.
Title : Stability of ondansetron hydrochloride in portable infusion-pump reservoirs.
Reference : Am J Hosp Pharm ; 49: 1471-1473. 1992

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 
No visual inspection

List of drugs
InjectionOndansetron hydrochloride Antiemetic
Stability in solutions Polyvinyl chloride Sodium chloride 0,9% 0,24 mg/ml 30°C Not specified
24 Hour
Stability in solutions Polyvinyl chloride Sodium chloride 0,9% 0,24 mg/ml 3°C Protect from light
30 Day
Stability in solutions Polyvinyl chloride None 2 mg/ml 30°C Not specified
7 Day