Type : Journal

Research teams : Los Angeles - University of Southern california, School of Pharmacy
Authors : Jhee SS, Jeong EW, Chin A, Inagaki K, Fox JL, Gill MA.
Title : Stability of ondansetron hydrochloride stored in a disposable, elastomeric infusion device at 4°C.
Reference : Am J Hosp Pharm ; 50: 1918-1920. 1993

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
InjectionOndansetron hydrochloride Antiemetic
Stability in solutions Polyisoprene elastomer NaCl 0,9% or Glucose 5% 0,03 & 0,3 mg/ml 4°C Light
14 Day