Last update :
18/04/2024
References   References 3753  
Type : Manufacturer

Research teams :
Authors :
Title : Tedizolid phosphate (Sivextro®) - Summary of Product Characteristics
Reference : Cubist Pharmaceuticals 2014

Level of Evidence : 
Manufacturer's stability data
Physical stability : 
Chemical stability : 
Other methods : 
Comments : 

List of drugs
InjectionCalcium chloride Electrolyte
Incompatible + InjectionTedizolid phosphate
InjectionCalcium glucoheptonate Electrolyte
Incompatible + InjectionTedizolid phosphate
InjectionCalcium gluconate Electrolyte
Incompatible + InjectionTedizolid phosphate
InjectionFolinate calcium Cytoprotective
Incompatible + InjectionTedizolid phosphate
InjectionLevofolinate calcium Cytoprotective
Incompatible + InjectionTedizolid phosphate
InjectionMagnesium sulfate Electrolyte
Incompatible + InjectionTedizolid phosphate
InjectionTedizolid phosphate Antibiotic
Factors which affect stability Solvent Ringer’s lactate solution Induces Degradation
Stability in solutions Glass Water for Injection 50 mg/ml 2-8°C Not specified
24 Hour
Stability in solutions Glass Water for Injection 50 mg/ml 25°C Not specified
24 Hour
Stability in solutions Not specified Sodium chloride 0,9% 0,8 mg/ml 2-8°C Not specified
24 Hour
Stability in solutions Not specified Sodium chloride 0,9% 0,8 mg/ml 25°C Not specified
24 Hour
Incompatible + InjectionCalcium chloride
Incompatible + InjectionCalcium glucoheptonate
Incompatible + InjectionCalcium gluconate
Incompatible + InjectionFolinate calcium
Incompatible + InjectionLevofolinate calcium
Incompatible + InjectionMagnesium sulfate

  Mentions Légales